1EPA High Performance Std.- Summer MOB5a_H I/M Program Options (Feb-95) 0I/M program #1 selected: I/M program #2 selected: 0Start year (Jan 1): 1983 Start year (Jan 1): 1983 Pre-1981 stringency: 20% Pre-1981 stringency: 20% First MYR covered: 1968 First MYR covered: 1986 Last MYR covered: 2020 Last MYR covered: 2020 Waiver (pre-1981): 3.% Waiver (pre-1981): 3.% Waiver (1981+): 3.% Waiver (1981+): 3.% Compliance Rate: 96.% Compliance Rate: 96.% Inspection type: Inspection type: Test Only Test Only Inspection frequency: Annual Inspection frequency: Annual I/M program #1 vehicle types I/M program #2 vehicle types LDGV - Yes LDGV - Yes LDGT1 - Yes LDGT1 - Yes LDGT2 - Yes LDGT2 - Yes HDGV - No HDGV - No 1981 & later MYR test type: 1981 & later MYR test type: 2500 rpm / Idle IM240 test Cutpoints, HC: 220.000 Cutpoints, HC: 0.800 Cutpoints, CO: 1.200 Cutpoints, CO: 20.000 Cutpoints, NOx: 999.000 Cutpoints, NOx: 2.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Press 1983 1983-2020 Yes Yes Yes No Test Only Annual 96.0% Purge 1983 1986-2020 Yes Yes Yes No Test Only Annual 96.0% ATP 1983 1984-2020 Yes Yes Yes No Test Only Annual 96.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: No 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 0.91 0.78 1.09 0.87 2.76 0.57 0.65 2.10 5.33 1.050 Exhaust HC: 0.62 0.56 0.81 0.63 1.60 0.57 0.65 2.10 2.26 0.709 Evaporat HC: 0.12 0.08 0.11 0.09 0.59 2.61 0.158 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.10 0.06 0.09 0.07 0.21 0.094 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 8.28 8.04 10.34 8.70 18.07 1.51 1.54 11.00 18.94 8.850 Exhaust NOX: 1.02 0.92 1.26 1.02 4.24 1.24 1.20 7.76 0.85 1.269 ________________________________________________________________________________________________________________ 1EPA High Performance Std.- Winter MOB5a_H I/M Program Options (Feb-95) 0 -M 83 Comment: + One or more evaporative temperatures (input daily maximum, input ambient, calculated hot soak, and/or calculated running loss) is 40F or less, or input daily minimum is 25F or less; no evaporative emission factors (hot soak, diurnal, running loss, or resting loss) will be calculated. 0I/M program #1 selected: I/M program #2 selected: 0Start year (Jan 1): 1983 Start year (Jan 1): 1983 Pre-1981 stringency: 20% Pre-1981 stringency: 20% First MYR covered: 1968 First MYR covered: 1986 Last MYR covered: 2020 Last MYR covered: 2020 Waiver (pre-1981): 3.% Waiver (pre-1981): 3.% Waiver (1981+): 3.% Waiver (1981+): 3.% Compliance Rate: 96.% Compliance Rate: 96.% Inspection type: Inspection type: Test Only Test Only Inspection frequency: Annual Inspection frequency: Annual I/M program #1 vehicle types I/M program #2 vehicle types LDGV - Yes LDGV - Yes LDGT1 - Yes LDGT1 - Yes LDGT2 - Yes LDGT2 - Yes HDGV - No HDGV - No 1981 & later MYR test type: 1981 & later MYR test type: 2500 rpm / Idle IM240 test Cutpoints, HC: 220.000 Cutpoints, HC: 0.800 Cutpoints, CO: 1.200 Cutpoints, CO: 20.000 Cutpoints, NOx: 999.000 Cutpoints, NOx: 2.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Press 1983 1983-2020 Yes Yes Yes No Test Only Annual 96.0% Purge 1983 1986-2020 Yes Yes Yes No Test Only Annual 96.0% ATP 1983 1984-2020 Yes Yes Yes No Test Only Annual 96.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: No 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 38. (F) Maximum Temp: 38. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of Jan. 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 38.0 / 38.0 / 38.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 16.2 / 20.0 / 16.2 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.14 1.07 1.52 1.20 2.74 0.58 0.63 2.10 2.80 1.245 Exhaust HC: 1.10 1.03 1.49 1.17 2.50 0.58 0.63 2.10 2.80 1.205 Evaporat HC: 0.01 0.00 0.00 0.00 0.01 0.00 0.006 Refuel L HC: 0.03 0.04 0.04 0.04 0.22 0.034 Runing L HC: 0.00 0.00 0.00 0.00 0.00 0.000 Rsting L HC: 0.00 0.00 0.00 0.00 0.00 0.00 0.000 Exhaust CO: 14.84 15.51 18.98 16.52 22.63 1.43 1.44 11.01 25.24 15.459 Exhaust NOX: 1.26 1.14 1.56 1.26 4.64 1.27 1.18 8.03 0.99 1.507 ________________________________________________________________________________________________________________ 1EPA Low Performance Std.- Summer MOB5a_H I/M Program Options (Feb-95) 0I/M program selected: 0 Start year (January 1): 1983 Pre-1981 MYR stringency rate: 20% First model year covered: 1968 Last model year covered: 2020 Waiver rate (pre-1981): 3.% Waiver rate (1981 and newer): 3.% Compliance Rate: 96.% Inspection type: Test Only Inspection frequency Annual Vehicle types covered: LDGV - Yes LDGT1 - Yes LDGT2 - Yes HDGV - No 1981 & later MYR test type: Idle Cutpoints, HC: 220.000 CO: 1.200 NOx: 999.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate ATP 1983 1968-2020 Yes Yes Yes No Test Only Annual 96.0% 0Air pump system disablements: No Catalyst removals: No Fuel inlet restrictor disablements: No Tailpipe lead deposit test: No EGR disablement: Yes Evaporative system disablements: No PCV system disablements: No Missing gas caps: No 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.39 1.19 1.66 1.33 2.76 0.57 0.65 2.10 5.33 1.484 Exhaust HC: 0.95 0.85 1.24 0.97 1.60 0.57 0.65 2.10 2.26 1.016 Evaporat HC: 0.19 0.14 0.18 0.15 0.59 2.61 0.221 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.17 0.12 0.16 0.13 0.21 0.157 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 12.97 11.80 15.46 12.86 18.07 1.51 1.54 11.00 18.94 13.042 Exhaust NOX: 1.38 1.24 1.69 1.37 4.24 1.24 1.20 7.76 0.85 1.599 ________________________________________________________________________________________________________________ 1EPA Low Performance Std.- Winter MOB5a_H I/M Program Options (Feb-95) 0 -M 83 Comment: + One or more evaporative temperatures (input daily maximum, input ambient, calculated hot soak, and/or calculated running loss) is 40F or less, or input daily minimum is 25F or less; no evaporative emission factors (hot soak, diurnal, running loss, or resting loss) will be calculated. 0I/M program selected: 0 Start year (January 1): 1983 Pre-1981 MYR stringency rate: 20% First model year covered: 1968 Last model year covered: 2020 Waiver rate (pre-1981): 3.% Waiver rate (1981 and newer): 3.% Compliance Rate: 96.% Inspection type: Test Only Inspection frequency Annual Vehicle types covered: LDGV - Yes LDGT1 - Yes LDGT2 - Yes HDGV - No 1981 & later MYR test type: Idle Cutpoints, HC: 220.000 CO: 1.200 NOx: 999.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate ATP 1983 1968-2020 Yes Yes Yes No Test Only Annual 96.0% 0Air pump system disablements: No Catalyst removals: No Fuel inlet restrictor disablements: No Tailpipe lead deposit test: No EGR disablement: Yes Evaporative system disablements: No PCV system disablements: No Missing gas caps: No 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 38. (F) Maximum Temp: 38. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of Jan. 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 38.0 / 38.0 / 38.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 16.2 / 20.0 / 16.2 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.73 1.62 2.30 1.82 2.74 0.58 0.63 2.10 2.80 1.800 Exhaust HC: 1.70 1.58 2.26 1.78 2.50 0.58 0.63 2.10 2.80 1.760 Evaporat HC: 0.01 0.00 0.00 0.00 0.01 0.00 0.006 Refuel L HC: 0.03 0.04 0.04 0.04 0.22 0.034 Runing L HC: 0.00 0.00 0.00 0.00 0.00 0.000 Rsting L HC: 0.00 0.00 0.00 0.00 0.00 0.00 0.000 Exhaust CO: 21.62 21.19 26.62 22.77 22.63 1.43 1.44 11.01 25.24 21.583 Exhaust NOX: 1.70 1.53 2.10 1.69 4.64 1.27 1.18 8.03 0.99 1.912 ________________________________________________________________________________________________________________ 1NJ 2002 EIMw/pressure Summer Centralized MOB5a_H I/M Program Options (Feb-95) 0 -M114 Warning: + Purge Check emission benefits assume the use of a dynomometer and the IM240 transient test procedure driving cycle. 0I/M program #1 selected: I/M program #2 selected: 0Start year (Jan 1): 1974 Start year (Jan 1): 1974 Pre-1981 stringency: 30% Pre-1981 stringency: 30% First MYR covered: 1941 First MYR covered: 1981 Last MYR covered: 2020 Last MYR covered: 2020 Waiver (pre-1981): 0.% Waiver (pre-1981): 0.% Waiver (1981+): 0.% Waiver (1981+): 3.% Compliance Rate: 98.% Compliance Rate: 98.% Inspection type: Inspection type: Test Only Test Only Inspection frequency: Biennial Inspection frequency: Biennial I/M program #1 vehicle types I/M program #2 vehicle types LDGV - Yes LDGV - Yes LDGT1 - Yes LDGT1 - Yes LDGT2 - Yes LDGT2 - Yes HDGV - Yes HDGV - No 1981 & later MYR test type: 1981 & later MYR test type: Idle ASM 5015/2525 Cutpoints, HC: 220.000 Cutpoints, HC: 50.000 Cutpoints, CO: 1.200 Cutpoints, CO: 15.000 Cutpoints, NOx: 999.000 Cutpoints, NOx: 2.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Press 1998 1970-2020 Yes Yes Yes No Test Only Biennial 98.0% Purge 2000 1981-2020 Yes Yes Yes No Test Only Biennial 98.0% ATP 1985 1975-2020 Yes Yes Yes Yes Test Only Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.10 0.92 1.26 1.02 2.58 0.57 0.65 2.10 5.33 1.204 Exhaust HC: 0.80 0.70 1.00 0.79 1.43 0.57 0.65 2.10 2.26 0.867 Evaporat HC: 0.11 0.08 0.10 0.09 0.58 2.61 0.155 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.10 0.06 0.08 0.07 0.21 0.092 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 10.04 9.45 12.09 10.21 15.86 1.51 1.54 11.00 18.94 10.345 Exhaust NOX: 1.14 1.02 1.40 1.13 4.09 1.24 1.20 7.76 0.85 1.374 ________________________________________________________________________________________________________________ 1NJ 2002 EIMw/pressure Summer Decentralized MOB5a_H I/M Program Options (Feb-95) 0 -M114 Warning: + Purge Check emission benefits assume the use of a dynomometer and the IM240 transient test procedure driving cycle. 0I/M program #1 selected: I/M program #2 selected: 0Start year (Jan 1): 1974 Start year (Jan 1): 1974 Pre-1981 stringency: 30% Pre-1981 stringency: 30% First MYR covered: 1941 First MYR covered: 1981 Last MYR covered: 2020 Last MYR covered: 2020 Waiver (pre-1981): 0.% Waiver (pre-1981): 0.% Waiver (1981+): 0.% Waiver (1981+): 3.% Compliance Rate: 98.% Compliance Rate: 98.% Inspection type: Inspection type: Computerized Test and Repair Computerized Test and Repair Inspection frequency: Biennial Inspection frequency: Biennial I/M program #1 vehicle types I/M program #2 vehicle types LDGV - Yes LDGV - Yes LDGT1 - Yes LDGT1 - Yes LDGT2 - Yes LDGT2 - Yes HDGV - Yes HDGV - No 1981 & later MYR test type: 1981 & later MYR test type: Idle ASM 5015/2525 Cutpoints, HC: 220.000 Cutpoints, HC: 50.000 Cutpoints, CO: 1.200 Cutpoints, CO: 15.000 Cutpoints, NOx: 999.000 Cutpoints, NOx: 2.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Press 1998 1970-2020 Yes Yes Yes No Test & Repair Biennial 98.0% Purge 2000 1981-2020 Yes Yes Yes No Test & Repair Biennial 98.0% ATP 1985 1975-2020 Yes Yes Yes Yes Test & Repair Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.30 1.06 1.49 1.18 2.63 0.57 0.65 2.10 5.33 1.381 Exhaust HC: 1.00 0.83 1.23 0.95 1.48 0.57 0.65 2.10 2.26 1.044 Evaporat HC: 0.11 0.08 0.10 0.09 0.58 2.61 0.155 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.10 0.06 0.08 0.07 0.21 0.092 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 13.44 11.80 15.72 12.94 16.70 1.51 1.54 11.00 18.94 13.337 Exhaust NOX: 1.31 1.13 1.57 1.26 4.11 1.24 1.20 7.76 0.85 1.521 ________________________________________________________________________________________________________________ 1NJ 2002 EIMw/o/pressure Summer Centralized MOB5a_H I/M Program Options (Feb-95) 0 -M114 Warning: + Purge Check emission benefits assume the use of a dynomometer and the IM240 transient test procedure driving cycle. 0I/M program #1 selected: I/M program #2 selected: 0Start year (Jan 1): 1974 Start year (Jan 1): 1974 Pre-1981 stringency: 30% Pre-1981 stringency: 30% First MYR covered: 1941 First MYR covered: 1981 Last MYR covered: 2020 Last MYR covered: 2020 Waiver (pre-1981): 0.% Waiver (pre-1981): 0.% Waiver (1981+): 0.% Waiver (1981+): 3.% Compliance Rate: 98.% Compliance Rate: 98.% Inspection type: Inspection type: Test Only Test Only Inspection frequency: Biennial Inspection frequency: Biennial I/M program #1 vehicle types I/M program #2 vehicle types LDGV - Yes LDGV - Yes LDGT1 - Yes LDGT1 - Yes LDGT2 - Yes LDGT2 - Yes HDGV - Yes HDGV - No 1981 & later MYR test type: 1981 & later MYR test type: Idle ASM 5015/2525 Cutpoints, HC: 220.000 Cutpoints, HC: 50.000 Cutpoints, CO: 1.200 Cutpoints, CO: 15.000 Cutpoints, NOx: 999.000 Cutpoints, NOx: 2.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Purge 2000 1981-2020 Yes Yes Yes No Test Only Biennial 98.0% ATP 1985 1975-2020 Yes Yes Yes Yes Test Only Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.20 1.00 1.37 1.11 2.58 0.57 0.65 2.10 5.33 1.293 Exhaust HC: 0.80 0.70 1.00 0.79 1.43 0.57 0.65 2.10 2.26 0.867 Evaporat HC: 0.17 0.13 0.16 0.14 0.58 2.61 0.203 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.15 0.10 0.13 0.11 0.21 0.133 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 10.04 9.45 12.09 10.21 15.86 1.51 1.54 11.00 18.94 10.345 Exhaust NOX: 1.14 1.02 1.40 1.13 4.09 1.24 1.20 7.76 0.85 1.374 ________________________________________________________________________________________________________________ 1NJ 2002 EIMw/o/pressure Summer Decentralized MOB5a_H I/M Program Options (Feb-95) 0 -M114 Warning: + Purge Check emission benefits assume the use of a dynomometer and the IM240 transient test procedure driving cycle. 0I/M program #1 selected: I/M program #2 selected: 0Start year (Jan 1): 1974 Start year (Jan 1): 1974 Pre-1981 stringency: 30% Pre-1981 stringency: 30% First MYR covered: 1941 First MYR covered: 1981 Last MYR covered: 2020 Last MYR covered: 2020 Waiver (pre-1981): 0.% Waiver (pre-1981): 0.% Waiver (1981+): 0.% Waiver (1981+): 3.% Compliance Rate: 98.% Compliance Rate: 98.% Inspection type: Inspection type: Computerized Test and Repair Computerized Test and Repair Inspection frequency: Biennial Inspection frequency: Biennial I/M program #1 vehicle types I/M program #2 vehicle types LDGV - Yes LDGV - Yes LDGT1 - Yes LDGT1 - Yes LDGT2 - Yes LDGT2 - Yes HDGV - Yes HDGV - No 1981 & later MYR test type: 1981 & later MYR test type: Idle ASM 5015/2525 Cutpoints, HC: 220.000 Cutpoints, HC: 50.000 Cutpoints, CO: 1.200 Cutpoints, CO: 15.000 Cutpoints, NOx: 999.000 Cutpoints, NOx: 2.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Purge 2000 1981-2020 Yes Yes Yes No Test & Repair Biennial 98.0% ATP 1985 1975-2020 Yes Yes Yes Yes Test & Repair Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.40 1.13 1.60 1.27 2.63 0.57 0.65 2.10 5.33 1.470 Exhaust HC: 1.00 0.83 1.23 0.95 1.48 0.57 0.65 2.10 2.26 1.044 Evaporat HC: 0.17 0.13 0.16 0.14 0.58 2.61 0.203 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.15 0.10 0.13 0.11 0.21 0.133 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 13.44 11.80 15.72 12.94 16.70 1.51 1.54 11.00 18.94 13.337 Exhaust NOX: 1.31 1.13 1.57 1.26 4.11 1.24 1.20 7.76 0.85 1.521 ________________________________________________________________________________________________________________ 1NJ 2002 EIMw/o/pressure Winter Centralized MOB5a_H I/M Program Options (Feb-95) 0 -M114 Warning: + Purge Check emission benefits assume the use of a dynomometer and the IM240 transient test procedure driving cycle. -M 83 Comment: + One or more evaporative temperatures (input daily maximum, input ambient, calculated hot soak, and/or calculated running loss) is 40F or less, or input daily minimum is 25F or less; no evaporative emission factors (hot soak, diurnal, running loss, or resting loss) will be calculated. 0I/M program #1 selected: I/M program #2 selected: 0Start year (Jan 1): 1974 Start year (Jan 1): 1974 Pre-1981 stringency: 30% Pre-1981 stringency: 30% First MYR covered: 1941 First MYR covered: 1981 Last MYR covered: 2020 Last MYR covered: 2020 Waiver (pre-1981): 0.% Waiver (pre-1981): 0.% Waiver (1981+): 0.% Waiver (1981+): 3.% Compliance Rate: 98.% Compliance Rate: 98.% Inspection type: Inspection type: Test Only Test Only Inspection frequency: Biennial Inspection frequency: Biennial I/M program #1 vehicle types I/M program #2 vehicle types LDGV - Yes LDGV - Yes LDGT1 - Yes LDGT1 - Yes LDGT2 - Yes LDGT2 - Yes HDGV - Yes HDGV - No 1981 & later MYR test type: 1981 & later MYR test type: Idle ASM 5015/2525 Cutpoints, HC: 220.000 Cutpoints, HC: 50.000 Cutpoints, CO: 1.200 Cutpoints, CO: 15.000 Cutpoints, NOx: 999.000 Cutpoints, NOx: 2.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Purge 2000 1981-2020 Yes Yes Yes No Test Only Biennial 98.0% ATP 1985 1975-2020 Yes Yes Yes Yes Test Only Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 38. (F) Maximum Temp: 38. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of Jan. 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 38.0 / 38.0 / 38.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 16.2 / 20.0 / 16.2 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.47 1.33 1.87 1.49 2.47 0.58 0.63 2.10 2.80 1.531 Exhaust HC: 1.43 1.30 1.84 1.45 2.24 0.58 0.63 2.10 2.80 1.491 Evaporat HC: 0.01 0.00 0.00 0.00 0.00 0.00 0.005 Refuel L HC: 0.03 0.04 0.04 0.04 0.22 0.034 Runing L HC: 0.00 0.00 0.00 0.00 0.00 0.000 Rsting L HC: 0.00 0.00 0.00 0.00 0.00 0.00 0.000 Exhaust CO: 17.38 17.62 21.55 18.76 19.88 1.43 1.44 11.01 25.24 17.642 Exhaust NOX: 1.40 1.26 1.74 1.40 4.49 1.27 1.18 8.03 0.99 1.636 ________________________________________________________________________________________________________________ 1NJ 2002 EIMw/o/pressure Winter Decentralized MOB5a_H I/M Program Options (Feb-95) 0 -M114 Warning: + Purge Check emission benefits assume the use of a dynomometer and the IM240 transient test procedure driving cycle. -M 83 Comment: + One or more evaporative temperatures (input daily maximum, input ambient, calculated hot soak, and/or calculated running loss) is 40F or less, or input daily minimum is 25F or less; no evaporative emission factors (hot soak, diurnal, running loss, or resting loss) will be calculated. 0I/M program #1 selected: I/M program #2 selected: 0Start year (Jan 1): 1974 Start year (Jan 1): 1974 Pre-1981 stringency: 30% Pre-1981 stringency: 30% First MYR covered: 1941 First MYR covered: 1981 Last MYR covered: 2020 Last MYR covered: 2020 Waiver (pre-1981): 0.% Waiver (pre-1981): 0.% Waiver (1981+): 0.% Waiver (1981+): 3.% Compliance Rate: 98.% Compliance Rate: 98.% Inspection type: Inspection type: Computerized Test and Repair Computerized Test and Repair Inspection frequency: Biennial Inspection frequency: Biennial I/M program #1 vehicle types I/M program #2 vehicle types LDGV - Yes LDGV - Yes LDGT1 - Yes LDGT1 - Yes LDGT2 - Yes LDGT2 - Yes HDGV - Yes HDGV - No 1981 & later MYR test type: 1981 & later MYR test type: Idle ASM 5015/2525 Cutpoints, HC: 220.000 Cutpoints, HC: 50.000 Cutpoints, CO: 1.200 Cutpoints, CO: 15.000 Cutpoints, NOx: 999.000 Cutpoints, NOx: 2.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Purge 2000 1981-2020 Yes Yes Yes No Test & Repair Biennial 98.0% ATP 1985 1975-2020 Yes Yes Yes Yes Test & Repair Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 38. (F) Maximum Temp: 38. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of Jan. 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 38.0 / 38.0 / 38.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 16.2 / 20.0 / 16.2 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.84 1.59 2.29 1.79 2.54 0.58 0.63 2.10 2.80 1.856 Exhaust HC: 1.80 1.55 2.26 1.76 2.31 0.58 0.63 2.10 2.80 1.817 Evaporat HC: 0.01 0.00 0.00 0.00 0.00 0.00 0.005 Refuel L HC: 0.03 0.04 0.04 0.04 0.22 0.034 Runing L HC: 0.00 0.00 0.00 0.00 0.00 0.000 Rsting L HC: 0.00 0.00 0.00 0.00 0.00 0.00 0.000 Exhaust CO: 22.35 21.17 26.97 22.86 20.94 1.43 1.44 11.01 25.24 22.041 Exhaust NOX: 1.61 1.40 1.94 1.56 4.51 1.27 1.18 8.03 0.99 1.817 ________________________________________________________________________________________________________________ 1NJ 2002 2500RPMw/pressure Summer Centralized MOB5a_H I/M Program Options (Feb-95) 0I/M program selected: 0 Start year (January 1): 1974 Pre-1981 MYR stringency rate: 30% First model year covered: 1941 Last model year covered: 2020 Waiver rate (pre-1981): 0.% Waiver rate (1981 and newer): 3.% Compliance Rate: 98.% Inspection type: Test Only Inspection frequency Biennial Vehicle types covered: LDGV - Yes LDGT1 - Yes LDGT2 - Yes HDGV - No 1981 & later MYR test type: 2500 rpm / Idle Cutpoints, HC: 220.000 CO: 1.200 NOx: 999.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Press 1998 1970-2020 Yes Yes Yes No Test Only Biennial 98.0% ATP 1985 1975-2020 Yes Yes Yes No Test Only Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.24 1.02 1.41 1.13 2.76 0.57 0.65 2.10 5.33 1.336 Exhaust HC: 0.88 0.75 1.08 0.84 1.60 0.57 0.65 2.10 2.26 0.941 Evaporat HC: 0.14 0.10 0.13 0.11 0.59 2.61 0.178 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.14 0.09 0.12 0.10 0.21 0.126 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 11.32 10.34 13.31 11.20 18.07 1.51 1.54 11.00 18.94 11.519 Exhaust NOX: 1.37 1.17 1.63 1.30 4.24 1.24 1.20 7.76 0.85 1.577 ________________________________________________________________________________________________________________ 1NJ 2002 2500RPMw/pressure Summer Decentralized MOB5a_H I/M Program Options (Feb-95) 0I/M program selected: 0 Start year (January 1): 1974 Pre-1981 MYR stringency rate: 30% First model year covered: 1941 Last model year covered: 2020 Waiver rate (pre-1981): 0.% Waiver rate (1981 and newer): 3.% Compliance Rate: 98.% Inspection type: Computerized Test and Repair Inspection frequency Biennial Vehicle types covered: LDGV - Yes LDGT1 - Yes LDGT2 - Yes HDGV - No 1981 & later MYR test type: 2500 rpm / Idle Cutpoints, HC: 220.000 CO: 1.200 NOx: 999.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate Press 1998 1970-2020 Yes Yes Yes No Test & Repair Biennial 98.0% ATP 1985 1975-2020 Yes Yes Yes No Test & Repair Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.40 1.13 1.60 1.27 2.76 0.57 0.65 2.10 5.33 1.478 Exhaust HC: 1.05 0.86 1.27 0.98 1.60 0.57 0.65 2.10 2.26 1.083 Evaporat HC: 0.14 0.10 0.13 0.11 0.59 2.61 0.178 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.14 0.09 0.12 0.10 0.21 0.126 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 14.10 12.26 16.35 13.45 18.07 1.51 1.54 11.00 18.94 13.948 Exhaust NOX: 1.43 1.21 1.69 1.35 4.24 1.24 1.20 7.76 0.85 1.627 ________________________________________________________________________________________________________________ 1NJ 2002 2500RPMw/o/pressure Summer Centralized MOB5a_H I/M Program Options (Feb-95) 0I/M program selected: 0 Start year (January 1): 1974 Pre-1981 MYR stringency rate: 30% First model year covered: 1941 Last model year covered: 2020 Waiver rate (pre-1981): 0.% Waiver rate (1981 and newer): 3.% Compliance Rate: 98.% Inspection type: Test Only Inspection frequency Biennial Vehicle types covered: LDGV - Yes LDGT1 - Yes LDGT2 - Yes HDGV - No 1981 & later MYR test type: 2500 rpm / Idle Cutpoints, HC: 220.000 CO: 1.200 NOx: 999.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate ATP 1985 1975-2020 Yes Yes Yes No Test Only Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.32 1.08 1.50 1.20 2.76 0.57 0.65 2.10 5.33 1.409 Exhaust HC: 0.88 0.75 1.08 0.84 1.60 0.57 0.65 2.10 2.26 0.941 Evaporat HC: 0.19 0.14 0.18 0.15 0.59 2.61 0.221 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.17 0.12 0.16 0.13 0.21 0.157 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 11.32 10.34 13.31 11.20 18.07 1.51 1.54 11.00 18.94 11.519 Exhaust NOX: 1.37 1.17 1.63 1.30 4.24 1.24 1.20 7.76 0.85 1.577 ________________________________________________________________________________________________________________ 1NJ 2002 2500RPMw/o/pressure Summer Decentralized MOB5a_H I/M Program Options (Feb-95) 0I/M program selected: 0 Start year (January 1): 1974 Pre-1981 MYR stringency rate: 30% First model year covered: 1941 Last model year covered: 2020 Waiver rate (pre-1981): 0.% Waiver rate (1981 and newer): 3.% Compliance Rate: 98.% Inspection type: Computerized Test and Repair Inspection frequency Biennial Vehicle types covered: LDGV - Yes LDGT1 - Yes LDGT2 - Yes HDGV - No 1981 & later MYR test type: 2500 rpm / Idle Cutpoints, HC: 220.000 CO: 1.200 NOx: 999.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate ATP 1985 1975-2020 Yes Yes Yes No Test & Repair Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 71. (F) Maximum Temp: 95. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of July 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 75.0 / 75.0 / 75.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 20.6 / 27.3 / 20.6 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.49 1.20 1.69 1.34 2.76 0.57 0.65 2.10 5.33 1.551 Exhaust HC: 1.05 0.86 1.27 0.98 1.60 0.57 0.65 2.10 2.26 1.083 Evaporat HC: 0.19 0.14 0.18 0.15 0.59 2.61 0.221 Refuel L HC: 0.03 0.04 0.05 0.04 0.31 0.043 Runing L HC: 0.17 0.12 0.16 0.13 0.21 0.157 Rsting L HC: 0.05 0.03 0.03 0.03 0.04 0.45 0.047 Exhaust CO: 14.10 12.26 16.35 13.45 18.07 1.51 1.54 11.00 18.94 13.948 Exhaust NOX: 1.43 1.21 1.69 1.35 4.24 1.24 1.20 7.76 0.85 1.627 ________________________________________________________________________________________________________________ 1NJ 2002 2500RPMw/o/pressure Winter Centralized MOB5a_H I/M Program Options (Feb-95) 0 -M 83 Comment: + One or more evaporative temperatures (input daily maximum, input ambient, calculated hot soak, and/or calculated running loss) is 40F or less, or input daily minimum is 25F or less; no evaporative emission factors (hot soak, diurnal, running loss, or resting loss) will be calculated. 0I/M program selected: 0 Start year (January 1): 1974 Pre-1981 MYR stringency rate: 30% First model year covered: 1941 Last model year covered: 2020 Waiver rate (pre-1981): 0.% Waiver rate (1981 and newer): 3.% Compliance Rate: 98.% Inspection type: Test Only Inspection frequency Biennial Vehicle types covered: LDGV - Yes LDGT1 - Yes LDGT2 - Yes HDGV - No 1981 & later MYR test type: 2500 rpm / Idle Cutpoints, HC: 220.000 CO: 1.200 NOx: 999.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate ATP 1985 1975-2020 Yes Yes Yes No Test Only Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 38. (F) Maximum Temp: 38. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of Jan. 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 38.0 / 38.0 / 38.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 16.2 / 20.0 / 16.2 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.61 1.42 2.02 1.59 2.74 0.58 0.63 2.10 2.80 1.663 Exhaust HC: 1.58 1.38 1.98 1.56 2.50 0.58 0.63 2.10 2.80 1.623 Evaporat HC: 0.01 0.00 0.00 0.00 0.01 0.00 0.006 Refuel L HC: 0.03 0.04 0.04 0.04 0.22 0.034 Runing L HC: 0.00 0.00 0.00 0.00 0.00 0.000 Rsting L HC: 0.00 0.00 0.00 0.00 0.00 0.00 0.000 Exhaust CO: 19.22 18.95 23.35 20.23 22.63 1.43 1.44 11.01 25.24 19.329 Exhaust NOX: 1.69 1.45 2.02 1.61 4.64 1.27 1.18 8.03 0.99 1.884 ________________________________________________________________________________________________________________ 1NJ 2002 2500RPMw/o/pressure Winter Decentralized MOB5a_H I/M Program Options (Feb-95) 0 -M 83 Comment: + One or more evaporative temperatures (input daily maximum, input ambient, calculated hot soak, and/or calculated running loss) is 40F or less, or input daily minimum is 25F or less; no evaporative emission factors (hot soak, diurnal, running loss, or resting loss) will be calculated. 0I/M program selected: 0 Start year (January 1): 1974 Pre-1981 MYR stringency rate: 30% First model year covered: 1941 Last model year covered: 2020 Waiver rate (pre-1981): 0.% Waiver rate (1981 and newer): 3.% Compliance Rate: 98.% Inspection type: Computerized Test and Repair Inspection frequency Biennial Vehicle types covered: LDGV - Yes LDGT1 - Yes LDGT2 - Yes HDGV - No 1981 & later MYR test type: 2500 rpm / Idle Cutpoints, HC: 220.000 CO: 1.200 NOx: 999.000 0Functional Check Program Description: 0Check Start Model Yrs Vehicle Classes Covered Inspection Comp (Jan1) Covered LDGV LDGT1 LDGT2 HDGV Type Freq Rate ATP 1985 1975-2020 Yes Yes Yes No Test & Repair Biennial 98.0% 0Air pump system disablements: No Catalyst removals: Yes Fuel inlet restrictor disablements: Yes Tailpipe lead deposit test: No EGR disablement: No Evaporative system disablements: No PCV system disablements: No Missing gas caps: Yes 0Stage II program selected: 0 Start year (January 1): 1989 Phase-in period (yrs.): 1 Percent Efficiency for LDGV & LDGT: 85.% Percent Efficiency for HDGV: 0.% 0[ ] Minimum Temp: 38. (F) Maximum Temp: 38. (F) Period 1 RVP: 9.0 Period 2 RVP: 9.0 Period 2 Start Yr: 1989 0VOC HC emission factors include evaporative HC emission factors. 0________________________________________________________________________________________________________________ 0Emission factors are as of Jan. 1st of the indicated calendar year. 0User supplied veh registration distributions. 0Cal. Year: 2002 I/M Program: Yes Ambient Temp: 38.0 / 38.0 / 38.0 (F) Region: Low Anti-tam. Program: Yes Operating Mode: 16.2 / 20.0 / 16.2 Altitude: 500. Ft. Reformulated Gas: Yes ASTM Class: C 0 Veh. Type: LDGV LDGT1 LDGT2 LDGT HDGV LDDV LDDT HDDV MC All Veh + ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ Veh. Speeds: 19.6 19.6 19.6 19.6 19.6 19.6 19.6 19.6 VMT Mix: 0.668 0.181 0.074 0.031 0.004 0.005 0.022 0.015 0Composite Emission Factors (Gm/Mile) VOC HC: 1.91 1.63 2.37 1.85 2.74 0.58 0.63 2.10 2.80 1.927 Exhaust HC: 1.88 1.60 2.33 1.81 2.50 0.58 0.63 2.10 2.80 1.887 Evaporat HC: 0.01 0.00 0.00 0.00 0.01 0.00 0.006 Refuel L HC: 0.03 0.04 0.04 0.04 0.22 0.034 Runing L HC: 0.00 0.00 0.00 0.00 0.00 0.000 Rsting L HC: 0.00 0.00 0.00 0.00 0.00 0.00 0.000 Exhaust CO: 23.30 21.86 27.90 23.61 22.63 1.43 1.44 11.01 25.24 22.921 Exhaust NOX: 1.76 1.49 2.09 1.67 4.64 1.27 1.18 8.03 0.99 1.946 ________________________________________________________________________________________________________________