General
Requirement |
Condition-
ally
Exempt Small Quantity Generator (CESQG)
[261.5] |
Small
Quantity Generator (SQG) |
Large
Quantity Generator (LQG) |
EPA ID Number
Required or Not? |
No - voluntary
See NJX program information |
Yes - click here |
Yes - click here |
Is a Hazardous
Waste Manifest Required?
(Manifest Information) |
No - Voluntary
See NJX
program information |
Yes - unless
waste
is reclaimed
pursuant to
[262.20(e)(1)] |
Yes
[262.20] |
Manifest Copy
Retention |
None - voluntary |
3 years [
262.40(a)] |
3 years
[262.40(a)] |
Exception Reporting
(failing to receive copy of manifest with TSDF operator
signature) |
None |
None - but within
60
days
generator must
submit copy of manifest with
note that signed
TSDF copy is
missing
[262.42(b)] |
1) generator
must contact
initial transporter
or theTSDF
operator within
35
days of
shipping date
[262.42(a)] 2)
generator must
submit written exception report
within
45 days
of shipping date to NJDEP
[262.42(a)] |
Land Disposal
Restriction
notification/
certification accompanying
shipments |
None |
Required for
certain
hazardous wastes.
Keep
your copy for
5 years
[268.7] |
Required for
certain
hazardous wastes.
Keep your copy
for 5 years
[268.7] |
Biennial Report
(Hazardous
Waste Report
Help) |
None |
None
[262.44] |
Submitted on each even
year to report
on manifest
activity for
previous
odd year
[262.41] |
Inspections
(inspecting your own facility) |
None |
Weekly for
Hazardous
waste storage containers
[265.174]
Daily / weekly for
hazardous waste storage tanks
log is required
[265.201(c)] |
Weekly for haz.
waste
storage containers
[265.174]
Daily/bimonthly/
yearly
for hazardous waste storage tanks
log is required
[265.195] |
Hazardous
Waste Training |
None |
Basic - waste
handling
familiarization & emergency
procedures (no drills
required)
[262.34(d)(5)(iii)] |
Full training (no drills
required)
[265.16] |
Preparedness
& Prevention |
None |
Familiarize fire,
police,
hospital
& have
emergency
response contractor
agreement (formal fire inspection not required)
[265.30-37] |
Familiarize fire, police,
hospital & have emergency response contractor
agreement (formal fire inspection not required)
[265.30-37] |
Contingency
Plan |
None |
Basic plan
[262.34(d)(5)(ii)]
Keep by the phone:
 |
Emergency Coordinator
- name &
- telephone # |
 |
Fire department
telephone # |
 |
Location of fire extinguisher |
 |
Location of alarm |
 |
Location of spill equipment |
|
Complete plan
[265.50-56] |